Varnost izdelkov (GPSR)
Proizvajalčeva koda: 2746977
EAN koda: 4017918472788
Registrirana blagovna znamka: Phoenix Contact
Ime proizvajalca: PHOENIX CONTACT Deutschland GmbH
Naslov proizvajalca: Flachsmarktstr. 8
Poštna številka proizvajalca: 32825
Kraj proizvajalca: Blomberg
Država proizvajalca: Germany
Telefon proizvajalca: +4905235300
Elektronski kontakt proizvajalca: https://www.phoenixcontact.com/
Kontakt odgovorne osebe za varnost: [email protected]
Država odgovorne osebe za varnost: Nemčija
Dokumenti
Podatkovna tablica 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Upute za rad i sigurnost 3579452 Phoenix Contact 2746977 IBS SUPI 3 LS
Tehnički podaci
| Tip |
IBS SUPI 3 LS |
|---|---|
| Pogonski napon | |
| Dužina |
12 mm |
| Širina |
12 mm |
| Vrsta zaštite |
IP00 |
| dim. |
(D x Š) 12 mm x 12 mm |
| Proizvođač-br. dijela |
2746977 |
| Sadržaj |
160 St. |
| Frequency measurement |
FALSE |
| Suitable for safety functions |
FALSE |
| Voltage type (supply voltage) |
DC |
| Supporting protocol for LON |
FALSE |
| Number of HW-interfaces industrial Ethernet |
0 |
| Number of HW-interfaces RS-232 |
0 |
| Number of HW-interfaces RS-422 |
0 |
| Number of HW-interfaces RS-485 |
0 |
| Number of HW-interfaces serial TTY |
0 |
| Number of HW-interfaces USB |
0 |
| Number of HW-interfaces parallel |
0 |
| Number of HW-interfaces other |
0 |
| With optical interface |
FALSE |
| Supporting protocol for TCP/IP |
FALSE |
| Supporting protocol for ASI |
FALSE |
| Supporting protocol for PROFIBUS |
FALSE |
| Supporting protocol for CAN |
FALSE |
| Supporting protocol for INTERBUS |
TRUE |
| Supporting protocol for KNX |
FALSE |
| Supporting protocol for Modbus |
FALSE |
| Supporting protocol for Data-Highway |
FALSE |
| Supporting protocol for DeviceNet |
FALSE |
| Supporting protocol for SUCONET |
FALSE |
| Supporting protocol for other bus systems |
FALSE |
| Number of functions |
0 |
| Explosion safety category for gas |
None |
| Explosion safety category for dust |
None |
| Fieldbus connection over separate bus coupler possible |
TRUE |
| System accessory |
TRUE |
| Appendant operation agent (Ex ia) |
FALSE |
| Appendant operation agent (Ex ib) |
FALSE |
| Degree of protection (IP) |
IP00 |
| Supporting protocol for SERCOS |
FALSE |
| Supporting protocol for INTERBUS-Safety |
FALSE |
| Number of interfaces PROFINET |
0 |
| Number of HW-interfaces wireless |
0 |
| Function block automatic reset |
FALSE |
| Function block contactless working protection installation |
FALSE |
| Function block operating mode selection |
FALSE |
| Function block emergency stop |
FALSE |
| Function block restart blockage |
FALSE |
| Function block access control |
FALSE |
| Function block affirm push button |
FALSE |
| Function block 2-hand switching |
FALSE |
| IO link master |
FALSE |
| Performance level according to EN ISO 13849-1 |
None |
| Contactor control function block |
FALSE |
| Supporting protocol for AS-Interface Safety at Work |
FALSE |
| Supporting protocol for DeviceNet Safety |
FALSE |
| Supporting protocol for EtherNet/IP |
FALSE |
| Supporting protocol for Foundation Fieldbus |
FALSE |
| Supporting protocol for PROFINET CBA |
FALSE |
| Supporting protocol for PROFINET IO |
FALSE |
| Supporting protocol for PROFIsafe |
FALSE |
| Supporting protocol for SafetyBUS p |
FALSE |
| Supply voltage DC |
5-5 V |
| SIL according to IEC 61508 |
None |
| Supporting protocol for EtherCAT |
FALSE |

0 od 5