Opis
Komunikacijski procesor CP 343-1 Lean za povezivanje SIMATIC S7-300 s Industrial Ethernet putem TCP/IP i UDP, multicast, SEND/RECEIVE sa i bez RFC1006, dohvaćanje/pisanje, S7 komunikacija (poslužitelj), PROFINET IO uređaj integriran 2. port prekidač ERTEC 200, zamjena modula bez PG-a, SNMP dijagnostika, inicijalizacija preko LAN-a, 2x RJ45 veza za LAN sa 10/100 Mbit/s
Ovaj tekst je strojno preveden.
Navodila za uporabo
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Podatkovna tablica 1745110 Siemens 6GK7343-1CX10-0XE0 PLC komunikacijski procesor
Tehnički podaci
Vrsta zaštite |
IP20 |
---|---|
Tip |
6GK7343-1CX10-0XE0 |
Min. temperatura okoline |
0 °C |
Maks. temperatura okoline |
+60 °C |
Proizvođač-br. dijela |
6GK73431CX100XE0 |
Montaža |
S7-300 šinu |
dim. |
(D x Š) 120 mm x 40 mm |
Dužina |
120 mm |
Širina |
40 mm |
Width |
40 |
Height |
125 mm |
Depth |
120 mm |
Suitable for safety functions |
FALSE |
Supporting protocol for LON |
FALSE |
Number of HW-interfaces industrial Ethernet |
2 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
0 |
With optical interface |
FALSE |
Supporting protocol for TCP/IP |
TRUE |
Supporting protocol for ASI |
FALSE |
Supporting protocol for PROFIBUS |
FALSE |
Supporting protocol for CAN |
FALSE |
Supporting protocol for INTERBUS |
FALSE |
Supporting protocol for KNX |
FALSE |
Supporting protocol for Modbus |
FALSE |
Supporting protocol for Data-Highway |
FALSE |
Supporting protocol for DeviceNet |
FALSE |
Supporting protocol for SUCONET |
FALSE |
Supporting protocol for other bus systems |
TRUE |
Redundancy |
FALSE |
Transmission rate |
100000000 kBit/s |
With potential separation |
FALSE |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Appendant operation agent (Ex ia) |
FALSE |
Appendant operation agent (Ex ib) |
FALSE |
Supporting protocol for SERCOS |
FALSE |
Supporting protocol for INTERBUS-Safety |
FALSE |
Number of interfaces PROFINET |
2 |
Number of HW-interfaces Wireless |
0 |
Radio standard Bluetooth |
FALSE |
Radio standard Wi-Fi 802.11 |
FALSE |
IO link master |
FALSE |
Performance level according to EN ISO 13849-1 |
None |
Supporting protocol for AS-Interface Safety at Work |
FALSE |
Supporting protocol for DeviceNet Safety |
FALSE |
Supporting protocol for EtherNet/IP |
FALSE |
Supporting protocol for Foundation Fieldbus |
FALSE |
Supporting protocol for PROFINET CBA |
FALSE |
Supporting protocol for PROFINET IO |
TRUE |
Supporting protocol for PROFIsafe |
FALSE |
Supporting protocol for SafetyBUS p |
FALSE |
Type of data transmission |
Other |
SIL according to IEC 61508 |
None |
Vrsta proizvoda |
PLC komunikacijski procesor |
0 od 5